Product Specifications 


 Operating and Testing Information
 Single or Multi-Stage Systems
 Specifications and Technical Data

 
 
Operating and Testing Information

Manifold and Quick-Connect Housing Assembly

Max. Operating Pressures:
Liquids: 125 psig @ 125 °F

Standard Pressure:
  1. Based upon static burst pressure
    of a minimum of 400 psig. No failures.
  2. Cyclic test of 12,000 cycles at 180 psig.
    Impulse pressure. No failures.

Note: Cyclic test based upon a fill rate of one cycle per second.

In-Line/Flow-Thru Assembly

Max. Operating Pressures:
Liquids: 125 psig @ 125 °F

Standard Pressure:
  1. Based upon static burst pressure
    of a minimum of 400 psig. No failures.
  2. Cyclic test of 12,000 cycles at 180 psig.
    Impulse pressure. No failures.

Note: Cyclic test based upon a fill rate of one cycle per second.

In addition to our own testing procedures, a highly respected independent filter manufacturer purchased housing assemblies and manifolds for testing and structural evaluation.

Independent Filter Manufacturer's Standard Testing
(Quick-Connect filter housing assemblies and manifolds only.)
  1. Burst Pressure - 400 psig
    slight leakage started at 355
    on one o-ring seal.
  2. Cyclic test of 71,200 cycles
    at 180 psig. No failures.¹
  3. Impulse pressure test
    of 74,282 cycles at 250 psig.
    No failures. (Weld on T-Bar
    attachment separated.)²
The R&D Senior Engineer
concludes in an
inter-office memo:
"Using standard company
test procedures, the units
exceeded the Mfr.'s claims
by a wide margin."
Independent filter manufacturers cyclic test is based on fill rate of two and one-half cycles per second.
¹ - Standard test is 10,000 cycles at 150 psig.
² - T-Bar attachment was mild steel, now is Stainless Steel.